All values measured to ground unless otherwise noted | |||
S2/1 | |||
Circuit 30 | Power input supplies ignition/starter switch | 12 VDC at all times | Feed from battery via X4 |
Circuit 50 | Power output activates starter relay | 12 VDC with starter lock-out relay energized, key in steering lock position "3" |
Note |
Circuit 15 | Power output, supplies several subsystems | 12 VDC with key in steering lock position "2" | |
G2 | |||
B+ | Circuit B+ power output, supplies circuit 30 and charges battery when engine is running | Ignition on 12 VDC when engine is running |
|
D+ | Circuit D+ signal output to charge indicator lamp A1e5 | Ignition on 12 VDC when engine is running, A1e5 not lit 0 VDC when engine is not running, A1e5 lit |
|
A1 | |||
1B.1 | Circuit D+ power input to charge indicator lamp A1e5 extinguishes when applied | Ignition on 12 VDC when engine is running, A1e5 not lit 0 VDC when engine is not running, A1e5 lit |
D+ is also processed into 61e as engine running recognition signal |
Note | Starter lock-out signal controlled from gear shifter in position P or N |