All values measured to ground unless otherwise noted
Conn./Plug/Pin Pin Information Test Value Comments
N15/3      
1.12 RPM sensor Y3/6n2 signal input, used additionally with wheel and engine rpms No or distorted signal from n2
will set DTC 012/108 on HHT
 
1.13 Power output to RPM sensors Y3/6n2, n3 Approx. 4-8 VDC with ignition on  
1.14 Switched ground output, activates Y3/6y3 valve Ignition off, ECM disconnected:
Approx. 2.5-6.5 Ohms to pin 1.38
 
1.15 Switched ground output activates Y3/6y4 valve Ignition off, ECM disconnected:
Approx. 2.5-6.5 Ohms to pin 1.38
 
1.16 Switched ground output activates Y3/6y5 valve Ignition off, ECM disconnected:
Approx. 2.5-6.5 Ohms to pin 1.38
 
1.17 Switched ground output activates Y3/6y6 valve Ignition off, ECM disconnected:
Approx. 2.5-4 Ohms to pin 1.38
PWM signal to regulate pressure
1.33 Sensor common ground signal output < 5 Ohm to ground  
1.34 Starter lock-out signal and transmission fluid temperature signal input > 20 kOhms in lever position P and N
approx. 0.5-2.5 kOhms in all other position measured to pin 1.33
 
1.35 RPM sensor Y3/6n3 signal input used additionally with wheel and engine rpms No or distorted signal from n3
will set DTC 013/109 on HHT
 
1.36 Switched ground output, activates Y3/6y1 valve Ignition off, ECM disconnected:
Approx. 4-8 Ohms to pin 1.38
 
1.37 Switched ground output, activates Y3/6y2 valve Ignition off, ECM disconnected:
Approx. 4-8 Ohms to pin 1.38
 
1.38 Power output supplies valves in valve unit Ignition on 12 VDC  
1.H CAN-Bus (high side). High speed data transfer bus input and output, shares data with other ECMs. No reliable test.
Check continuity to other ECMs.
Approx. 5 VAC when data is on bus.
Note 2
Also other ECMs can cause CAN-Bus DTCs.
1.L CAN-Bus (low side). High speed data transfer bus input and output, shares data with other ECMs.   HHT is also used for
CAN diagnosis
2.1 DTC diagnostic output
also input for HHT data and test
Ignition on 12 VDC,
approx. 8 VAC when data transmission active
Note 1
2.2-6 Pins not used    
2.7 Starter lock-out signal switched ground output, permits starting in lever position
"P" or "N" only
measure to circuit 30 approx. 12VDC
in lever position "P" or "N",
approx. 0 VDC in any other position
 
2.8-28 Pins not used    
2.29 Circuit 87 power input to ECM, switched by relay K40/4k1 Ignition on 12 VDC Feed from battery
2.30 Main ground to W29/2 Approx. 0 Ohms to ground  
Note 1 DTC memory of sporadic faults is reset with ignition off    
Note 2 CAN-Bus interchanging data:
Received
- Engine rpm
- Engine load
- VSS speed signal rear axle
- Accelerator pedal position
- Engine coolant temperature

Transmitted
- Engaged gear
- Overload protection requirements
- Kick-down
- Limp-home mode