All values measured to ground unless otherwise noted
Conn./Plug/Pin Pin Information Test Value Comments
S16/1      
1 Circuit 15 input supplies backup lamp function Ignition on 12 VDC Feed from F3f29
2 Backup lamp signal output Ignition on lever in position R - 12 VDC see also S16/1 pin1
3-7 pins not used    
8
9
Circuit 50 starter lockout signal input
Circuit 50 starter lockout signal output
Lever pos P or N 12 VDC with key held in
start position
Note 1
S16/6      
2
4
Kickdown enable power input from BM enables kickdown valve depending upon engine rpm and speed signal Engine at idle 12 VDC
Engine off < 1 VDC
 
S65      
1
2
Transmission overload protection signal input, to reduce power in case of AT overload Engine at idle, gear range selector in pos
P or N > 4 VDC, D < 1 VDC
 
Note 1 As of MY 93 relay K38 is installed. Activation from ATA system