All values measured to ground unless otherwise noted
Conn./Plug/Pin Pin Information Test Value Comments
K40/4      
A1.1 Main ground Approx. 0 Ohms to ground see also Pin B2.5
A1.2 Main ground Approx. 0 Ohms to ground see also Pin B2.5
A1.3 Circuit 87 switched power output to Z7/35,
supplies motor management components
Engine running 12 VDC Feed from battery, circuit protected by K40f5
A1.4 Circuit 15 fused power output to Z3/29,
supplies motor management components
Ignition on 12 VDC Circuit protected by K40f6
A1.5 Circuit 87 fused power output, supplies motor management components Ignition on 12 VDC Circuit protected by K40f4
A1.6 Starter lock-out signal output enables start procedure Ignition on 12 VDC
When starer turning 0 VDC
 
A1.7 Air pump voltage supply, switched by relay K40k3 12 VDC with pump running Feed from battery, Circuit protected by K40f7
A2.2,3 Pins not used    
B1.1 Pin not used    
B1.2 Circuit 30z power output to diagnostic connectors 12 VDC at all times Circuit protected by K40f1
B1.3 Air pump relay 86 signal, activated by N3/10 ECM Disconnect ECT sensor and connect 2.5 KOhms resistor across pin 1 and 4 of B11/4 plug
engine at idle, measure to circuit 87 pin A.2
12 VDC while pump is running (approx. 2 min)
see also Pin B2.4
B1.4 Fuel pump activation signal input, energizes K27 Ignition on 0.1-0.3 A current draw
measure to pin B1.10 12 VDC for approx. 1 sec.
Start engine 12 VDC during start process and when engine is running
Note 1
B1,
5,
6
Pins not used    
B1.7 Signal from "Diagnostic port" of Traction system to diagnostic connector (see also Pin H1.2) Ignition on 12 VDC To be tested with
HHT refer to D.M.
B1.8 Pin not used    
B1.9 Main Ground to W16/4 Approx. 0 Ohms to ground  
B1.10 Circuit 87 switched power input from Z7/35, energizes K27 Ignition on 0.1-0.3 A current draw
measure to pin B1.4 12 VDC for approx. 1 sec.
Start engine 12 VDC during start process and when engine is running
Note 1
B2.1 Pin not used    
B2.2 Circuit 87 fused power output to Z7/36, supplies motor management components Ignition on 12 VDC Circuit protected by K40f4
B2.3 Circuit 87 switched power output to fuel pump, switched by relay K40k1, controlled by engine ECM Engine running 12 VDC Feed from battery, fuse protected by K40f5
B2.4 Air pump relay 85 signal, activated by N3/10 ECM Disconnect ECT sensor and connect 2.5 KOhms resistor across pin 1 and 4 of B11/4 plug
engine at idle, measure to circuit 87 pin A.2
12 VDC while pump is running (approx. 2 min)
see also Pin B1.3
B2.5 Main ground to W16/6 Approx. 0 Ohms to ground  
C.1 Circuit 30 main power input 12 VDC at all times Feed from battery
C.2 Circuit 30 power output to engine control module 12 VDC at all times See also Pin C.1
C.3 Circuit 15 main power input Ignition on 12 VDC Feed from S2/1 via Z3/4
C.4 Circuit 30 power input 12 VDC at all times Feed from F1f29 via X12/3
D.2,3 Pins not used    
E.1 Pin not used    
F1.1 Pin not used    
F1.2 Fuel pump activation signal output, energizes K27 Ignition on 0.1-0.3 A current draw
measure to pin F1.4 12 VDC for approx. 1 sec.
Start engine 12 VDC during start process and when engine is running
Note 1
F1.3 Pin not used    
F1.4 Circuit 87 switched power input from Z7/35 via B1.10, energizes K27 Ignition on 0.1-0.3 A current draw
measure to pin F1.2 12 VDC for approx. 1 sec.
Start engine 12 VDC during start process and when engine is running
Note 1
F2.1,2 Pins not used    
F2.3 Circuit 87 power output to AT ECM and components, switched by relay K40/4k1 Ignition on 12 VDC  
F2.4 Pin not used    
F2.5 Circuit 15 U unfused power output to Transmission Range Recognition Switch Ignition on 12 VDC  
G.1,2 Pins not used    
H1.1 Fused power output to stop lamp switch (normally closed) Ignition on, 12 VDC with brakes not applied,
0 VDC with brakes applied.
Circuit protected by K40f2
H1.2 Signal from "Diagnostic port" of Traction system (see also Pin B1.7) Ignition on 12 VDC To be tested with
HHT refer to D.M.
H2 Fused power output to Traction systems   Circuit protected by K40f2
I.1 Starter lock-out switched ground signal input enables start procedure Ignition on 12 VDC
When starer turning 0 VDC
 
I.2 Circuit 87 M1 switched power input Ignition on 12 VDC Switched by relay K40/1 via Z7/35
Note 1 Activation of the FP occurs only once after
ignition "ON". For next activation, engine
must have run briefly.