All values measured to ground unless otherwise noted
Conn./Plug/Pin Pin Information Test Value Comments
N10/1      
1.1-4 Pins not used    
1.5 Hazard flasher switch signal input S6/1s1 ON < 1 Ohm, OFF > 20 kOhms  
1.6 Interior CL switch signal input Interior CL switch in:
Rest position > 20 kOhms
lock pos. approx. 200 Ohms
unlock pos. < 1 Ohm
 
1.7 HCS switch ground signal input Approx. 0 Ohms with HCS switch depressed  
1.8 Hazard flasher control lamp output S6/1s1 ON 12 VDC intermittent  
2.1 Rear window defroster switch signal input Ignition on, 6.2-8 VDC with N22s1 held in pressed position, < 1 VDC in rest position  
2.2 Rear window defroster signal output, lights LED in A/C ECM Ignition on, rear window defroster on:
7.2-9.2 VDC
 
2.3 Pin not used    
2.4 Left turn signal indicator voltage output Ignition on, 12 VDC intermittent with left turn signal on A1e1 flashing
Note 1
2.5 Right turn signal indicator voltage output Ignition on, 12 VDC intermittent with right turn signal on A1e2 flashing
Note 1
2.6 CAN Class B bus (high side). Mid speed data transfer bus input and output, exchanges data with EIS ECM No reliable test. Check continuity to all appropriate ECMs. Approx. 5 VAC when data is on bus Note 2
2.7 CAN Class B bus (low side) See pin 2.6  
3.1 Auxilliary fan control module activation signal output Ignition on 12 VDC  
3.2 Auxilliary fan control module control signal output    
4.1 CAN Class B bus (low side). Mid speed data transfer bus input and output, exchanges data with other ECMs No reliable test. Check continuity to all appropriate ECMs. Approx. 5 VAC when data is on bus  
4.2 CAN Class B bus (high side) See pin 4.1  
4.3-6 Pins not used    
4.7 Right rear turn signal lamp voltage output Ignition on, 12 VDC intermittent with right turn signal on E4e1 flashing
Note 1
4.8 Left rear turn signal lamp voltage output Ignition on, 12 VDC intermittent with left turn signal on E3e1 flashing
Note 1
5.1 Right front turn signal/side marker lamp voltage output Ignition on, 12 VDC intermittent with right turn signal on E6/2 flashing
Note 1
5.2 Pin not used    
5.3 Left front turn signal/side marker lamp voltage output Ignition on, 12 VDC intermittent with left turn signal on E6/1 flashing
Note 1
5.4 Pin not used    
SAM Fixed connection to driver-side fuse and relay module    
Note 1 Turn signal/hazard warning flasher frequencies:
1.5 Hz (90/min) with all turn lights ok.
3.0 Hz (180/min) one or more turn lights defective.
   
Note 2 N73 is gateway for data exchange between CAN Class B and Class C bus