All values measured to ground unless otherwise noted | |||
N7 | |||
3.1 3.2 |
Circuit 56b, fused voltage input, left low beam right low beam |
Lights on, S1 in pos II, S4 in low beam pos 12 VDC |
Feed from S1 pin 1 via S4s3 to F1f32 left, F1f31 right |
3.3-5 | Pins not used | ||
3.6 | Exterior lighting failure signal, switched ground | Approx. 0 Ohms to ground with one or more exterior lighting lamps defective | Lights A1e14 |
3.7 | Circuit 58, left tail/parking lamp fused voltage input | Lights on, S1 in pos I or II, 12 VDC | same as pin 2.8 |
3.8-11 | Pins not used | ||
3.12 | Circuit 15 fused power input | Ignition on 12 VDC | Feed from F1f19 |
3.13 | Main ground to W1 | Approx. 0 Ohms to ground | |
3.14 | Circuit 61e voltage decoupled signal input | 12 VDC with generator running | Feed from generator via IC |
3.15 | Pin not used | ||
3.16 | Circuit 58, right tail/parking lamp fused voltage input | Lights on, S1 in pos I or II, 12 VDC | same as pin 2.16 |
3.17 | Circuit 54, stop lamp switched voltage input | 12 VDC with brakes applied | same as pin 2.10 & 2.11 |
3.18 | Pin not used | ||
Note 1 | On exterior lighting failure check power supply for N7-1, fuses in N7-1, and light bulbs first. | ||
Note 2 | For pins not listed see diagram PE82.10-U-2000EB |