All values measured to ground unless otherwise noted | |||
N7 | |||
1.1 | Left front turn signal lamp voltage supply | 12 VDC intermittent with hazard flasher on Ignition on: 12 VDC intermittent with left turn signal on |
see pin 1.6 |
1.2,3 | Pins not used | ||
1.4 1.5 |
Circuit 56b voltage supply output, Right front low beam lamp Left front low beam lamp |
Lights on, S1 in pos II, S4 in low beam pos 12 VDC |
activated from S1 pin 1 via S4 , fused by F1f31 and f32 feed to N7 3.1/3.2 |
1.6 | Right front turn signal lamp voltage supply | 12 VDC intermittent with hazard flasher on Ignition on: 12 VDC intermittent with right turn signal on |
Feed from S4/s1 orS6, see diagram PE82.10-2200 |
1.7-10 | Pins not used | ||
2.1-6 | Pins not used | ||
2.7 2.8 |
Circuit 58, left taillamp voltage supply auxiliary taillamp tail/parking lamp |
Lights on, S1 in pos I or II, 12 VDC |
Feed from S1 pin 10 via F1f25 to pin 3.7 |
2.10 2.11 |
Circuit 54, stop lamp voltage supply Left stop lamp Right stop lamp |
12 VDC with brakes applied | Feed from F1f19 via S9/1 to pin 3.17 |
2.14 | Pin not used | ||
2.15 2.16 |
Circuit 58, right taillamp voltage supply auxiliary taillamp tail/parking lamp |
Lights on, S1 in pos I or II, 12 VDC | Feed from S1 pin 3 via F1f24 to pin 3.16 |
Note 1 | On exterior lighting failure check power supply for N7-1, fuses in N7-1, and light bulbs first. | ||
Note 2 | For pins not listed see diagram PE82.10-U-2000EB |