All values measured to ground unless otherwise noted | |||
N7 | |||
1.1 | Left front turn signal lamp voltage supply | 12 VDC intermittent with hazard flasher on Ignition on: 12 VDC intermittent with left turn signal on |
see pin 1.6 |
1.2,3 | Pins not used | ||
1.4 1.5 |
Circuit 56b voltage supply output, Right front low beam lamp Left front low beam lamp |
Lights on, S1 in pos II, S4 in low beam pos 12 VDC |
activated from S1 pin 1 via S4 , fused by F1f4 and f5 feed to N7 3.1/3.2 |
1.6 | Right front turn signal lamp voltage supply | 12 VDC intermittent with hazard flasher on Ignition on: 12 VDC intermittent with right turn signal on |
Feed from S4/s1 orS6, see diagram PE82.10-2200 |
1.7-10 | Pins not used | ||
2.1-6 | Pins not used | ||
2.7 2.8 |
Circuit 58, left taillamp voltage supply auxiliary taillamp tail/parking lamp |
Lights on, S1 in pos I or II, 12 VDC |
Feed from S1 pin 10 via F1f16 to pin 3.7 |
2.10 2.11 |
Circuit 54, stop lamp voltage supply Left stop lamp Right stop lamp |
12 VDC with brakes applied | Feed from F1f3 via S9/1 to pin 3.17 |
2.14 | Circuit 54, center high mounted stop lamp voltage supply | 12 VDC with brakes applied | |
2.15 2.16 |
Circuit 58, right taillamp voltage supply auxiliary taillamp tail/parking lamp |
Lights on, S1 in pos I or II, 12 VDC | Feed from S1 pin 3 via F1f15 to pin 3.16 |
3.1 3.2 |
Circuit 56b, fused voltage input, left low beam right low beam |
Lights on, S1 in pos II, S4 in low beam pos 12 VDC |
Feed from S1 pin 1 via S4s3 to F1f5 left, F1f4 right |
3.3-5 | Pins not used | ||
3.6 | Exterior lighting failure signal, switched ground | Approx. 0 Ohms to ground with one or more exterior lighting lamps defective | Lights A1e14 |
3.7 | Circuit 58, left tail/parking lamp fused voltage input | Lights on, S1 in pos I or II, 12 VDC | same as pin 2.8 |
3.8-11 | Pins not used | ||
3.12 | Circuit 15 fused power input | Ignition on 12 VDC | Feed from F1f3 |
3.13 | Main ground to W1 | Approx. 0 Ohms to ground | |
3.14 | Circuit 61e voltage decoupled signal input | 12 VDC with generator running | Feed from generator via IC |
3.15 | Pin not used | ||
3.16 | Circuit 58, right tail/parking lamp fused voltage input | Lights on, S1 in pos I or II, 12 VDC | same as pin 2.16 |
3.17 | Circuit 54, stop lamp switched voltage input | 12 VDC with brakes applied | same as pin 2.10 & 2.11 |
3.18 | Pin not used |