All values measured to ground unless otherwise noted
Conn./Plug/Pin Pin Information Test Value Comments
A1      
1.22 Circuit 58d output, "Dimmed Instrument Illumination" voltage.
hot with exterior lights on
Varies up to 12 VDC, depending on setting of dimming value or ambient brightness. Short protected, current decoupled from circ. 58k
Note
E15/2      
1.1 Rear door contact switch signal input All doors closed 12 VDC
any door open < 1 VDC
Note 1
1.2 Left/right rear dome lamp on/off signal output Measure to circuit 30 pin 1.2
turn rear dome lamp switch on 12 VDC
 
1.3 Interior dome lamp activation signal input Lock vehicle < 1 VDC, E15/2 will not be lit
Unlock vehicle > 12 VDC, E15/2 will be lit
 
1.4 Circuit 58d input,
illuminates position of operation elements
Varies from 0.5-12 VDC, depending on setting of dimming value with exterior lights on  
1.5 Front door contact switch signal input All doors closed 12 VDC
any door open < 1 VDC
Note 1
1.6 Circuit 15 main power input Ignition on 12 VDC Feed from F1f35
1.7 Main ground to W19 Approx. 0 Ohms to ground  
1.8 Circuit 30 main power input 12 VDC at all times Feed from F1f27 via Z7/1
2.1
2.2
Vanity mirrors power output Ignition on 12 VDC
mirror illumination can be activated
 
3.1
3.2
Front door entrance/exit lamps input    
Note Signal is feed to solder splice Z81 and distributed to operating elements.
For better location of those elements, especially at nighttime, most of them are illuminated when exterior lights on
   
Note 1 Interior lamps are switched on/off when locking or unlocking vehicle using key or remote control, or opening any front door.
Dome lamp extinguishes (soft dim) with delay of approx. 8 sec