All values measured to ground unless otherwise noted
Conn./Plug/Pin Pin Information Test Value Comments
A37      
1.8 CAN Class B bus (high side). Mid speed data transfer bus input and output, exchanges data with other ECMs No reliable test. Check continuity of wiring. Approx. 5 VAC when data is on bus HHT is also used for
CAN diagnosis
1.9 CAN Class B bus (low side) See pin 1.8  
1.14 Left front door contact switch ground signal input Ignition off approx. 0 Ohms when door is open  
1.16 Right front door contact switch ground signal input Ignition off approx. 0 Ohms when door is open  
2.2 Circuit 30 main power input 12 VDC at all times Feed from F4f4
2.3 Main ground to W7 Approx. 0 Ohms to ground  
2.4 Circuit 30 fused power input 12 VDC at all times Feed from F4f2
N69/1      
1.1 Circuit 30 main power input 12 VDC at all times Feed from F1f8
1.3 Main ground to W18 Approx. 0 Ohms to ground  
3.1
3.5
L/F door entrance/exit lamp (+) output
L/F door entrance/exit lamp (-) output
Door contact switch N70s2 on:
12 VDC with left front door open
E17/9 illuminated
3.9 CAN Class B bus (low side). Mid speed data transfer bus input and output, exchanges data between various ECMs No reliable test. Check continuity to all appropriate ECMs. Approx. 5 VAC when data is on bus  
3.18 CAN Class B bus (high side) See pin S3.9  
N69/2      
1.1 Circuit 30 main power input 12 VDC at all times Feed from F4f3
1.3 Main ground to W19 Approx. 0 Ohms to ground  
3.1
3.5
R/F door entrance/exit lamp (+) output
R/F door entrance/exit lamp (-) output
Door contact switch N70s2 on:
12 VDC with right front door open
E17/10 illuminated
3.9 CAN Class B bus (low side). Mid speed data transfer bus input and output, exchanges data between various ECMs No reliable test. Check continuity to all appropriate ECMs. Approx. 5 VAC when data is on bus  
3.18 CAN Class B bus (high side) See pin S3.9  
N70      
A.1 Main ground to W19 Approx. 0 Ohms to ground  
A.2 Circuit 30 power input 12 VDC at all times Feed from F1f9
A.3 CAN Class B bus (low side). Mid speed data transfer bus input and output, exchanges data with other ECMs No reliable test. Check continuity of wiring. Approx. 5 VAC when data is on bus  
A.6 CAN Class B bus (high side) See pin A.3  
Note 1 Due to various functions A37, N69/1-4 and N70 are split up in several system diagrams, therefore only the relating pins are listed. Pins not shown are unrelated to this system