All values measured to ground unless otherwise noted
Conn./Plug/Pin Pin Information Test Value Comments
N22      
1.1 "Diagnostic port" for readout and diagnostic purpose. No reliable test.
Check continuity to X11/4 pin 16.
Note 1
  Stored DTC data's are memory persistent    
1.2-6 Pins not used    
1.7 Voltage output, supplies refrigerant pressure sensor. Ignition on, 5 VDC. Leads to B12 via
1.8-10 Pins not used    
1.11 Circuit 15x, power input. Ignition on, 12 VDC. Feed from F1f18
1.12-15 Pins not used    
1.16 Refrigerant pressure sensor signal input, used to protect A/C compressor when pressure drops. Approx. 0-5 VDC depending on actual pressure value. Feed from B12 pin 2
1.17 VSS signal input Ignition on, lift front of vehicle.
Turn left front wheel > 1 rev/sec by hand > 3 VAC or with vehicle moving
 
1.18 Pin not used    
1.19 Sensors common ground, in A/C system. Approx. 12 VDC to pin 2.8. Feed from Z6/16
1.20 In-car temperature signal input, controls aspirator blower. NTC. Decreasing resistance with increasing temperature.
Approx. 20 kOhms at 10 °C,
approx. 4.5 kOhms at 45 °C.
Note 1
1.21 Outside temperature signal input. NTC. Decreasing resistance with increasing temperature.
Approx. 5.5 kOhms at 10 °C,
approx. 1.5 kOhms at 45 °C.
Note 1
1.22 Evaporator temperature signal input. NTC. Decreasing resistance with increasing temperature.
Approx. 9 kOhms at 0 °C,
approx. 1.2 kOhms at 45 °C.
Note 1
1.23 Heater core signal input, left side. NTC. Decreasing resistance with increasing temperature.
Approx. 20 kOhms at 10 °C,
approx. 4.5 kOhms at 45 °C.
Note 1
1.25 RPM signal input. Engine running at idle speed.
Approx. 5-7.5 VDC.
Note 1
 
1.26
1.27
A/C compressor rpm sensor
signal input low side
signal input high side
Disconnect ECM measure across pin 26 and 27
approx. 185 Ohms or
engine at idle > 0.04 VAC
Voltage and
frequency increases
when rpm raises
2.1 Signal output, blower speed control. Ignition on.
> 0.7 VDC with blower set to "min".
> 5.0 VDC with blower set to "max".
 
2.2,3 Pins not used    
 
2.4
2.5
Recirculated air flap switchover valve
Valve (short stroke)
Valve (long stroke)
Ignition on.
< 1V
< 1V
 
2.6 Blend air flap valve Ignition ON
Switch on Display "LO" 11-14V
Measure across pins 2.6 and 2.18
 
2.7 Auxiliary fan relay stage 1 activation signal output Ignition on, set air volume selector to min
< 1 VDC L/R fans running at low speed
 
2.8 Circuit 30, main power input. 12 VDC all times. Feed from F1f12
2.9 Circuit 15, power input. Ignition on, 12 VDC. Feed from F1f2
via Z3/11
2.10 RPM increase signal output. Idle speed increases with A/C compressor on. Engine running.
12 VDC with A/C compressor on (defrost mode),
0 VDC with A/C compressor off (defrost "off").
 
2.11-12 Pins not used    
 
2.13
2.14
Footwell flap switchover valve
Valve (short stroke)
Valve (long stroke)
Ignition on.
11-14V
11-14V
 
2.15 Diverter flap valve Ignition ON
Switch on Display "HI" <1V
Measure across pins 2.15 and 2.18
 
2.16 Auxiliary fan relay stage 2 activation signal output Ignition on, set air volume selector to max
< 1 VDC L/R fans running at high speed
 
2.17 Circuit 58d input, "Dimmed Instrument Illumination" voltage.  
Varies up to 12 VDC, depending on setting of dimming value or ambient brightness.
 
Short protected, current decoupled from circ. 58k
2.18 Switchover valve unit power supply output Ignition on, 12 VDC  
2.19 Main ground to W1. Approx. 0 Ohms to ground.  
2.20 Switched ground signal output, activates circulation pump. Ignition off.
Approx. 2-4 Ohms between pin 2.20 and 2.18. Check motor.
Pump runs when grounded (Ignition on)
 
2.21 Duovalve output Ignition ON
Switch on Display "HI" 11-14V
Switch on Display "LO" <1V
 
 
2.22
2.23
Defroster nozzle flap switchover valve
Valve (short stroke)
Valve (long stroke)
Ignition on.
< 1V
< 1V
 
2.24 Pin not used    
2.25 Voltage output, activates A/C compressor. A/C system on: Defrost on, EC off.
12 VDC with A/C compressor on.
0 VDC with A/C compressor off.
 
 
2.26-29 Pins not used.    
Note 1 Refer to D. M. Climate Control Vol. 1, 3.2