All values measured to ground unless otherwise noted | |||
N22 | |||
1.1 | "Diagnostic port" for readout and diagnostic purpose. | No reliable test. Check continuity to X11/4 pin 16. |
Note 1 |
![]() |
|||
1.2-6 | Pins not used | ||
1.7 | Voltage output, supplies refrigerant pressure sensor. | Ignition on, 5 VDC. | Leads to B12 via |
1.8-10 | Pins not used | ||
1.11 | Circuit 15x, power input. | Ignition on, 12 VDC. | Feed from F1f18 |
1.12-15 | Pins not used | ||
1.16 | Refrigerant pressure sensor signal input, used to protect A/C compressor when pressure drops. | Approx. 0-5 VDC depending on actual pressure value. | Feed from B12 pin 2 |
1.17 | VSS signal input | Ignition on, lift front of vehicle. Turn left front wheel > 1 rev/sec by hand > 3 VAC or with vehicle moving |
|
1.18 | Pin not used | ||
1.19 | Sensors common ground, in A/C system. | Approx. 12 VDC to pin 2.8. | Feed from Z6/16 |
1.20 | In-car temperature signal input, controls aspirator blower. | NTC. Decreasing resistance with increasing temperature. Approx. 20 kOhms at 10 °C, approx. 4.5 kOhms at 45 °C. |
Note 1 |
1.21 | Outside temperature signal input. | NTC. Decreasing resistance with increasing temperature. Approx. 5.5 kOhms at 10 °C, approx. 1.5 kOhms at 45 °C. |
Note 1 |
1.22 | Evaporator temperature signal input. | NTC. Decreasing resistance with increasing temperature. Approx. 9 kOhms at 0 °C, approx. 1.2 kOhms at 45 °C. |
Note 1 |
1.23 | Heater core signal input, left side. | NTC. Decreasing resistance with increasing temperature. Approx. 20 kOhms at 10 °C, approx. 4.5 kOhms at 45 °C. |
Note 1 |
1.25 | RPM signal input. | Engine running at idle speed. Approx. 5-7.5 VDC. |
Note 1 |
1.26 1.27 |
A/C compressor rpm sensor signal input low side signal input high side |
Disconnect ECM measure across pin 26 and 27 approx. 185 Ohms or engine at idle > 0.04 VAC |
Voltage and frequency increases when rpm raises |
2.1 | Signal output, blower speed control. | Ignition on. > 0.7 VDC with blower set to "min". > 5.0 VDC with blower set to "max". |
|
2.2,3 | Pins not used | ||
2.4 2.5 |
Recirculated air flap switchover valve Valve (short stroke) Valve (long stroke) |
Ignition on. < 1V < 1V |
|
2.6 | Blend air flap valve | Ignition ON Switch on Display "LO" 11-14V Measure across pins 2.6 and 2.18 |
|
2.7 | Auxiliary fan relay stage 1 activation signal output | Ignition on, set air volume selector to min < 1 VDC L/R fans running at low speed |
|
2.8 | Circuit 30, main power input. | 12 VDC all times. | Feed from F1f12 |
2.9 | Circuit 15, power input. | Ignition on, 12 VDC. | Feed from F1f2 via Z3/11 |
2.10 | RPM increase signal output. Idle speed increases with A/C compressor on. | Engine running. 12 VDC with A/C compressor on (defrost mode), 0 VDC with A/C compressor off (defrost "off"). |
|
2.11-12 | Pins not used | ||
2.13 2.14 |
Footwell flap switchover valve Valve (short stroke) Valve (long stroke) |
Ignition on. 11-14V 11-14V |
|
2.15 | Diverter flap valve | Ignition ON Switch on Display "HI" <1V Measure across pins 2.15 and 2.18 |
|
2.16 | Auxiliary fan relay stage 2 activation signal output | Ignition on, set air volume selector to max < 1 VDC L/R fans running at high speed |
|
2.17 | Circuit 58d input, "Dimmed Instrument Illumination" voltage. | Varies up to 12 VDC, depending on setting of dimming value or ambient brightness. |
Short protected, current decoupled from circ. 58k |
2.18 | Switchover valve unit power supply output | Ignition on, 12 VDC | |
2.19 | Main ground to W1. | Approx. 0 Ohms to ground. | |
2.20 | Switched ground signal output, activates circulation pump. | Ignition off. Approx. 2-4 Ohms between pin 2.20 and 2.18. Check motor. Pump runs when grounded (Ignition on) |
|
2.21 | Duovalve output | Ignition ON Switch on Display "HI" 11-14V Switch on Display "LO" <1V |
|
2.22 2.23 |
Defroster nozzle flap switchover valve Valve (short stroke) Valve (long stroke) |
Ignition on. < 1V < 1V |
|
2.24 | Pin not used | ||
2.25 | Voltage output, activates A/C compressor. | A/C system on: Defrost on, EC off. 12 VDC with A/C compressor on. 0 VDC with A/C compressor off. |
|
2.26-29 | Pins not used. | ||
Note 1 | Refer to D. M. Climate Control Vol. 1, 3.2 |