GF72.29-P-4001A | Lock-up recognition of power windows, function | 12.12.96 |
|
Function
The door control module (N69/1) or (N69/2), (with MODELS 202/210 also N69/3 or N69/4), receives pulses from the power windows for the position recognition. |
If these pulses are absent during the actuation of the motor in the power window for more than 1 sec, then the door control module detects the lock-up of the motor and switches it off.
|
![]() |
Position recognition of power windows | GF72.29-P-4000A | |
![]() |
Power windows in front doors | GF72.29-P-4101A | |
![]() |
Rear door control module | GF72.29-P-4102A | |
![]() |
Driver-side front door control module | GF72.29-P-4105A | |
![]() |
Passenger-side front door control module | GF72.29-P-4106A |