Function prerequisites
no overvoltage/undervoltage

Function
The close tilting/sliding roof function is only available in the normalized state of the tilting/sliding roof. It is triggered by pulling the tilting/sliding roof switch (N70s1) downward.
The overhead control panel control module (N70) then actuates the
  motor of the tilting/sliding roof (M12/1). The direction in which the motor is actuated depends on whether the sliding roof or the tilting roof is open. The motor is actuated until the overhead control panel control module (N70) through the position measurement detects that the tilting/sliding roof is closed, or lock-up of the tilting/sliding roof is detected.



Opening pop-up roof, function   GF77.20-P-2003A
Open sliding roof function   GF77.20-P-2004A
Sliding/pop-up roof lock-up recognition, function   GF77.20-P-3000A
Tilting/sliding roof (SR) position measurement, function   GF77.20-P-3001A
Tilting/sliding roof (SR) normalization, function   GF77.20-P-3002A
Tilting/sliding roof motor   GF77.20-P-4100A
Overhead control panel control module   GF82.20-P-4101A