GF82.70-P-2005AA | Cellular telephone (GSM 900 MHz) on/off characteristics, function | 17.3.00 |
|
On / off characteristics of D2B telephone (portable CTEL)
The characteristic of the D2B telephone in the D2B ring is solely dependent on the state of terminal 15 (ignition ON/OFF). Information regarding the state of terminal 15 is sent to the D2B interface portable CTEL (A59/1) from the Head Unit (COMAND/radio) via the D2B ring. The D2B interface portable CTEL (A59/1) is not electrically connected to terminal 15 and switches the portable CTEL on or off when commanded by the Head Unit, via the D2B ring or an external wake-up circuit. After the ignition is switched off the D2B interface portable CTEL (A59/1) and therefore the telephone remain switched on for an overshoot period of t=10 min. before being switched off. It is not possible to program another overshoot period because the interface's overshoot period is preprogrammed and unalterable. Neither is it possible to influence the on/off characteristic of the D2B telephone by programming the portable CTEL. System performance The portable CTEL D2B interface (A59/1) has three operating states. - Powerdown mode The interface is shut down with the exception of the external wake up circuit. |
- Idle or overshoot time mode
The remaining components in the D2B ring are switched off, only the interface remains active for t=10 min after switching off the D2B ring (ignition OFF). Each further key operation, during the overshoot period, extends the overshoot period by t=60 min. - Active mode Both the interface and the remaining components in the D2B ring are active and available to the user. Switch-on operation 1. Current state: ignition ON, portable CTEL D2B interface (A59/1) is in inactive mode (powerdown mode), the telephone system is not operational. The portable CTEL D2B interface (A59/1) is activated (active mode) when: - a portable CTEL, in switched-on state, is inserted into the portable CTEL's receptacle - a portable CTEL in the receptacle is switched on - a portable CTEL that is in the receptacle and switched on makes a call (incoming/outgoing) - a wake-up signal of another D2B ring subscriber is recognized via the external wake-up circuit |
2. Current state: ignition OFF, the portable CTEL D2B interface (A59/1) is in the overshoot phase (idle mode) and the D2B ring is in inactive mode (switched off)
The portable CTEL D2B interface (A59/1) is activated (active mode) when: - a portable CTEL that is in the receptacle and switched on makes a call (incoming/outgoing) - a wake-up signal of another D2B ring subscriber is recognized via the external wake-up circuit Switching-off process The portable CTEL D2B interface (A59/1) is in the overshoot phase (idle mode) and the D2B ring is switched off. The interface remains switched off for as long as there is no portable CTEL in the receptacle or when one is in the receptacle but not switched on. |
The following cases are possible depending on the status of terminal 15:
- Terminal 15 ON After expiry of the overshoot period of t=10 min (no further key operations on the portable CTEL during the overshoot period) the interface is switched off (powerdown mode). This does not alter the state of the portable CTEL in the receptacle, in other words, a portable CTEL in the receptacle and switched on remains switched on and is not switched off by the interface. - Terminal 15 OFF After expiry of the overshoot period of t=10 min (no further key operations on the portable CTEL during the overshoot period) the interface is switched off (powerdown mode). This alters the state of the portable CTEL in the receptacle, in other words, a portable CTEL in the receptacle is switched off by the interface. When the D2B ring is deactivated the portable CTEL D2B interface (A59/1) is switched off if a portable CTEL is not in the receptacle or if a portable CTEL is in the receptacle but not switched on. The interface remains active for the duration of the overshoot period, when a portable CTEL is inserted into the receptacle and switched on. |
Telephone interface, position/task/design/function | ![]() |