GF15.30-P-3000G | Starter control, function | 8.7.96 |
|
Shown on engine 111, 112
K40/4 Fuse and relay module Model 202, 208, 210 Model 163 designation F1 L5 Crankshaft position sensor M1 Starter (circuit 50) N3/4 HFM-SFI [HFM] control unit N3/10 ME-SFI control unit (shown) N65 Cycle module, model 170 S2/1 ignition/start switch (without DAS 3) |
![]() | |
P07.61-0386-06 |
Task
Interrupting the circuit (circuit 50) to the starter solenoid switch after engine start speed is reached (switching off starter). |
Design
The starter solenoid switch is actuated not through the ignition/starter switch, but through the starter relay by the engine control unit. The voltage for the starter relay (coil) is supplied through circuit 87. The starter relay is actuated by the engine control unit through GND. |
Function
When the ignition/start switch is turned from position 2 into the start position, start recognition is activated by the engine control unit through circuit 50. As soon as an engine start speed of 400 to 700 rpm is reached, the engine control unit interrupts the ground actuation to the starter relay and thus the start operation. |
![]() The starter control is only enabled when the clutch pedal is operated. When the clutch pedal is depressed, the clutch pedal switch is operated for start enable (S40/5). |
Start recognition function | Engine 111 ME, 112 | GF07.13-P-3014G |